Suva 407C, Klea 66. R-22 replacement AC. ASHRAE safety class A1, temperature glide about 11 °F. Gauge pressure at sea level.

ChargeCheck for iPhone is coming to the App Store.

°FLiquid / bubble (psig)Vapor / dew (psig)
-402.7-2.3
-355.1-0.4
-307.71.6
-2510.63.9
-2013.76.5
-1517.29.3
-1020.912.3
-525.015.7
029.519.4
534.323.5
1039.527.9
1545.232.7
2051.237.9
2557.743.5
3064.749.6
3572.256.1
4080.263.2
4588.870.7
5097.978.8
55107.687.5
60117.996.8
65128.9106.7
70140.5117.3
75152.8128.5
80165.8140.5
85179.6153.2
90194.1166.7
95209.4181.0
100225.5196.1
105242.4212.1
110260.2229.0
115278.9246.9
120298.6265.8
125319.2285.6
130340.7306.6
135363.3328.7
140387.0352.0
145411.7376.6
150437.5402.5

Negative values are inches of vacuum territory shown as negative psig. Use the dew column for superheat and the bubble column for subcooling. Try the superheat calculator.

Other refrigerants: R-410A · R-454B · R-32 · R-22 · R-134a · R-404A · R-507A · R-1234yf