Superheat & subcooling calculator

Gauge pressures, line temperatures and the manufacturer's target in; superheat, subcooling and "within / outside entered target range" out. 9 refrigerants, dew point for suction and bubble point for liquid.

Low side
High side
Manufacturer target subcoolingEnter the target subcooling from the unit nameplate or installation guide. This tool does not calculate targets. Tolerance defaults to ±3 °F; enter the manufacturer's if it differs.
ConditionsAir entering the condenser. Required for a range check; below 55 °F no check is made.
Enter liquid pressure and line temperatureSuperheat: - °F · Subcooling: - °FSuction sat (dew): - °F · Liquid sat (bubble): - °F

Safety: Readings are a guide only, for trained and certified HVAC/R technicians (for example EPA Section 608 in the US). This tool does not tell you to add or recover refrigerant. Always follow the equipment manufacturer's charging procedure and safety instructions. A2L refrigerants (R-32, R-454B) are mildly flammable.

ChargeCheck for iPhone is coming to the App Store.

How it works

Superheat = suction line temperature minus suction saturation temperature (dew point). Subcooling = liquid saturation temperature (bubble point) minus liquid line temperature.

The calculator does not work out a target and never says a charge is correct. You enter the target from the manufacturer: target superheat from the charging chart for a fixed orifice / piston, target subcooling from the nameplate or installation guide for a TXV / EEV. The controlling value is compared to that target ± tolerance (default ±5 °F superheat, ±3 °F subcooling). No check is made below 55 °F outdoor, on ductless / inverter systems (charged by weight), or on commercial and automotive refrigerants; superheat under 3 °F always shows "Check readings".

PT data: CoolProp 8.0 (NIST reference equations) and the Chemours R-454B table, checked against Arkema charts within 0.1 psi. See the R-410A PT chart.