R-1234yf PT chart
HFO-1234yf. Automotive, low-GWP systems. ASHRAE safety class A2L. Gauge pressure at sea level.
ChargeCheck for iPhone is coming to the App Store.
| °F | psig |
|---|---|
| -40 | -5.7 |
| -35 | -4.4 |
| -30 | -3.0 |
| -25 | -1.4 |
| -20 | 0.4 |
| -15 | 2.3 |
| -10 | 4.4 |
| -5 | 6.7 |
| 0 | 9.2 |
| 5 | 11.9 |
| 10 | 14.9 |
| 15 | 18.1 |
| 20 | 21.6 |
| 25 | 25.4 |
| 30 | 29.4 |
| 35 | 33.8 |
| 40 | 38.4 |
| 45 | 43.4 |
| 50 | 48.8 |
| 55 | 54.5 |
| 60 | 60.6 |
| 65 | 67.1 |
| 70 | 74.0 |
| 75 | 81.3 |
| 80 | 89.0 |
| 85 | 97.3 |
| 90 | 106.0 |
| 95 | 115.2 |
| 100 | 124.9 |
| 105 | 135.1 |
| 110 | 145.9 |
| 115 | 157.3 |
| 120 | 169.2 |
| 125 | 181.8 |
| 130 | 195.0 |
| 135 | 208.9 |
| 140 | 223.4 |
| 145 | 238.7 |
| 150 | 254.7 |
Negative values are inches of vacuum territory shown as negative psig. Use the dew column for superheat and the bubble column for subcooling. Try the superheat calculator.
Other refrigerants: R-410A · R-454B · R-32 · R-22 · R-134a · R-404A · R-407C · R-507A